Defective Tank Returned to Service

PROBLEM

Over many years the lower sections of this tank had suffered extreme corrosion, resulting in several through wall defects. In addition, the bit-sand bed had failed completely, increasing the likely hood of under base corrosion.

The client wanted the tank brought back into service, but internal access was impossible.

SOLUTION

RU Coated provided a system recommendation and included plate designs that would reinstate strength into the lower sections. Plates were bonded in place using Belzona 1121 in a “cold weld” application which avoided “Hot Works”.

After completing concrete repairs, a flexible Tank Base Seal was then installed to prevent under base corrosion. RU Coated provided support throughout and completed the final inspection to validate the application.

Project images

Proven results across diverse industries

From emergency leak repairs completed in under an hour to complex tank refurbishments, we deliver innovative solutions that work within your operational constraints.

Get In Touch